LCD Screen | ✔ | ||
Language Support | Turkish, English, Russian | ||
Battery | ✔ | ||
Real Time Clock | ✔ | ||
Password Protection | ✔ | ||
Current Transformer Ratio | 1 - 5000 | ||
Voltage Transformer Ratio | 1 - 5000 | ||
Demand Period | 1-60 min. adjustable | ||
Connection Type | 3F4T, 3F3T, Aron | ||
Measurements in Quadrants | 4 | ||
Number of Measurements in a Period | 512 | ||
LCD/Display Refresh Period | 1sn | ||
Networks | TT, TN, IT | ||
Phasor Diagram | ✔ | ||
Signal Waveforms | ✔ | ||
Min./Max./Demand Values | ✔ | ||
Number of Tariffs | 2 | ||
Multi Sub-Tariffs (Peak, Day and Off-Peak) | ✔ | ||
3Ø Phase Energy Meters | ✔ | ||
Measurement Range | 10mA - 6A AC | ||
Overvoltage Category | 300 V Cat II | ||
Measurement Surge Voltage | 2 kV | ||
Power Consumption | <0.2 VA | ||
Intermittent Overload | 100 A for 1 sec. | ||
Sampling Frequency between 45-65 Hz | 25.6 kHz | ||
Overvoltage Category | 300 V Cat III | ||
Measured Range L-N | 1-300 Vrms | ||
Measured Range L-L | 2-500 Vrms | ||
Measured Frequency Range | 45-65 Hz | ||
Power Consumption | <0.1 VA | ||
Sampling Frequency between 45-65 Hz | 25.6 kHz | ||
Harmonics for Current and Voltage Phases | Up to 51st | ||
THD - Voltage in % | ✔ | ||
THD - Current in % | ✔ | ||
According to IEC 61557-12 | Total Active Power | Class 0.2 | |
Total Reactive Power | Class 1 | ||
Total Apparent Power | Class 0.2 | ||
Total Active Energy | Class 0.5 | ||
Total Reactive Energy | Class 2 | ||
Frequency | Class 0.05 | ||
Current | Class 0.2 | ||
Neutral Current | Class 0.5 | ||
Voltage | Class 0.2 | ||
Power Factor | Class 0.5 | ||
THDV, THDI | Class 1 | ||
According to IEC 62053-22 | Total Active Energy | Class 0.2S | |
According to IEC 62053-23 | Total Reactive Energy | Class 2 | |
Alarm Relay Outputs | Number of Outputs | 2 | |
Type | NO (SPST) | ||
Max. Switching Current | 10 A | ||
Max. Switching Voltage | 250 VAC | ||
Max. Switching Power | 1250 VA | ||
Digital Inputs | Number of Inputs | 2 | |
Minimum Counting Frequency | 100 Hz, 10 ms | ||
Input Present or Not | Dry Contact | ||
Isolation Level | 5000 Vrms | ||
Digital Outputs | Number of Outputs | 2 | |
Type | Transistör | ||
Switching Voltage Range | 5-30 VDC | ||
Minimum Switching Frequency | 20 Hz, 50 ms | ||
Isolation Level | 5000 Vrms | ||
Voltage | AC | 85-300V | |
DC | 85-300V | ||
Consumption | AC | <3VA | |
DC | <2.5W | ||
Frequency | 45-65Hz | ||
Min./Max./Avg. Values | Hourly Records | 1920 Hours x 68 Different Paramaters | |
Daily Records | 240 Days x 68 Different Paramaters | ||
Monthly Records | 36 Months x 68 Different Parameters | ||
Demand | 4 Months x 16 Different Parameters | ||
Alarm Records | 50 | ||
Protocol | Modbus RTU | ||
Baud Rate | 2400-115200 bps adjustable | ||
Parity Number | None | ||
Stop Bit | 1 | ||
Address | 1-247 | ||
Isolation | 2750V RMS | ||
Weight (g) | 404 g | ||
Protection Class | Front IP40 / Rear IP20 | ||
Mounting Type | Panel Mount | ||
Supply, Voltage, Current, Relay Outputs | Stranded: | 2.5mm² - 14AWG | |
Solid: | 4mm² - 12AWG, 2x1.5mm² - 2x16AWG | ||
Digital I/O, RS 485, Analog Output | Stranded: | 1.5mm² - 16AWG | |
Solid: | 1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG | ||
Operating Temperature | -20 to +70°C | ||
Storing Temperature | -30 to +80°C | ||
Relative Humidity (No Condensation) | Maks. 95% | ||
300 VAC CAT II according to IEC 61010-1 | ✔ | ||
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11 | ✔ | ||
Network Connections | |||
Digital I/O and Alarm Output Connections | |||
3 wires with 3CTs | |||
4 wires with 3CTs | |||
3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and phase 3 in this figure. | |||
Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to phase 1 in this figure. | |||
Digital Output Connection | |||
Digital Input Connection | |||
Alarm Output Connection | |||
Analog Output Connection | |||